A   A   A   A    | Admin login | | General Data Protection Regulation | | Disclaimer | | Imprint | | Contact |
You are on: Ul-Engine > Ignition

Ignition

The ROTAX 912 has an integrated generator flange-mounted to the rear of the engine. The voltage generated by the charging coils is used to charge the on-board battery (instruments, starter, starter motor). Separate ignition coils are provided to generate the ignition voltage. The entire units have a dual design, i.e. it is redundant. One system can fail without the engine stopping. If an ignition unit fails, there is a small drop in speed, which can be checked during run-up by switching off one unit.

If the complete charging coils fail, the battery is no longer charged and is drained by connected consumers such as instruments. If the battery is empty, it is not possible to start the engine, all consumers no longer in function, but the engine would continue to run.

A 4-stroke engine must be ignited once every two crankshaft revolutions per cylinder. As the ROTAX 912 has 4 cylinders on one crankshaft, 2 ignition sparks are required per crankshaft revolution so that one spark plug per cylinder can be fired.

Double ignition is achieved by duplicating the trigger coils (A1/2 and A3/4) and trigger cam (1) in the ignition unit (B1/2 and B3/4) and (2). Coils (A/B) and cams (1/2) are staggered in depth so that pulses are only triggered if the levels of coil and cam are identical. This means that, as mentioned above, the ignition system is duplicated.

The staggered coils and cams are not visible in the top view. A 5th Trigger coil is in charge for the rev. counter. The firing order is 1 4 2 3 - see picture above. Although there are standards for the numbering of the cylinders, there are many different numberings. Whether old or new standard BRD DDR US or engine manufacturer, seen from the power take-off side or vice versa - the only decisive factor is what the engine manufacturer specifies.


Graphic: ROTAX 912 at MMH Sep 2022 74-00-00 IGNITION UNIT - the offset of the ignition pick-ups (Trigger coil) and sensors (Trigger cam) are not visible.
Graphic: ROTAX 912 at MMH Sep 2022 74-00-00 IGNITION UNIT - the offset of the ignition pick-ups (Trigger coil) and sensors (Trigger cam) are not visible.
Picture: with kind permission David R. Walker
Picture: with kind permission David R. Walker
The ignition times for start and continuous operation are determined by the cams. Once when the cam hits a coil in its level (operating) and once when the cam leaves this coil (start). The control unit (ignition box) determines how long the trailing edge of the cam is relevant at the start and then switches to the leading edge (signal on and off are processed).

Due to engine design, ignition occurs also at “the TDC of the exhaust stroke”, but this has no effect on engine operation. To understand how the two ignition modules "interlock" the cylinders and the upper and lower plugs, it is essential to study the documentation.See e.g. MMH 74-00-00 and 74-20-00.

The ignition timing and any soft-start device and its function can be found in the engine's technical manuals. This can be, for example, the current MMH (Maintenance Manual Heavy) for the relevant engine, which can be found at:


https://www.flyrotax.com/p/service/technical-documentation

Ignition map

ROTAX 912 engines with fuel injection have an improved ignition system. These engines (iS series) feature a redundant engine control unit not only for the fuel injection system but also for the ignition. The engine control unit (ECU) uses a map to determine the ignition timing based on the engine data. Particularly in the low and mid-range rev ranges, an adjusted ignition timing is necessary for smoother operation and to protect the engine.

Unfortunately, a map-controlled ignition system is not available for Rotax carburettor engines. Third-party suppliers do, however, offer a map-controlled ignition system specifically for the 912 carburettor engines. More information to follow shortly.

The article on the spark plug comparison that where here can now be found under UL-Engine => Spark Plugs

The link to the spark plug comparison is also still available here:


Spark Plug Comparison

ROTAX boxer engine  ⇐   |   ⇒  Spark Plugs

Cookies
No tracking cookies are used. Therefore, there is nothing to decline, accept, or select. Please note the General Data Protection Regulation Site.
Wisdoms
"Der Fehler, lieber Brutus, liegt nicht bei unseren Sternen, sondern bei uns selbst..."
William Shakespeare
Misconseptions
"Die Dinge haben nur den Wert, den man ihnen verleiht.”
Jean Baptiste Moliere
Schedules
Dt. Meisterschaft UL 20.-23. Aug. 26
https://www.deutsche-meisterschaft-ul.de

ROTAX Fly-In Wels 21.-23. Aug. 26
https://www.flyrotax.com/e/rotax-fly-in-austria-2026

Boller Fly-In 29. -30. Aug. 25
http://www.ulboll.de
Webhosting
Counter
001550299
Requests since release 2025